← Back to the model

MODEL 03 / FULL RECORDED TAKEOFF

Framing & drywall.
Measured in detail.

The full recorded partition, board, ceiling and accessory scope behind this framing model.

Anonymous model 03 matching this recorded takeoff
MODEL 03 / MATCHING PROJECT MEASUREMENTSOpen all 65 scope entries ↓
251.653LFNew partition centerlines · 33 runs
4,968.405SFKnown net wall board · two faces
781.638SFHorizontal gypsum ceiling
532.98SFAcoustic ceiling scope
Unpriced review example

Unpriced review example; field dimensions, assembly choices and open questions remain. 65 scope entries, supporting measurements and 6 open questions. Reference, projection and planning rows are identified so they are not added to installed scope twice.

01 / MEASUREMENTS

Every partition run. Its board calculation.

Select a wall for measured length, stated board height, gross area and opening deductions. Unknown-height rated walls remain open.

Anonymous redraw · one selected measurement at a time

The resized display is a measurement context, not a drawing to scale. Floor redraws retain simplified export geometry. The detailed source quantities and qualifications govern this review example.

Inspect all 33 measurement records
MeasurementTypeQuantityUnitLength LFHeight FTGross SFDeduction SFNet / bound SFDrawing
Partition7.703LF7.70312184.8848136.88A200 vectors / A700 details
Partition9.203LF9.20312220.880220.88A200 vectors / A700 details
Partition12.187LF12.18712292.48102.32190.16A200 vectors / A700 details
Partition9.203LF9.20312220.880220.88A200 vectors / A700 details
Partition10.333LF10.3331224848200A200 vectors / A700 details
Partition7.787LF7.78712186.880186.88A200 vectors / A700 details
Partition11.627LF11.62712279.0493.42185.62A200 vectors / A700 details
Partition4.56LF4.5612109.440109.44A200 vectors / A700 details
Partition2.797LF2.7971267.12067.12A200 vectors / A700 details
Partition3.893LF3.8931293.44093.44A200 vectors / A700 details
Partition8.2LF8.212196.80196.8A200 vectors / A700 details
Partition8.2LF8.212196.858.658138.142A200 vectors / A700 details
Partition15.43LF15.4312370.3296274.32A200 vectors / A700 details
Partition8.417LF8.4171220248154A200 vectors / A700 details
Partition8.417LF8.417122020202A200 vectors / A700 details
Partition10.287LF10.28712246.880246.88A200 vectors / A700 details
Partition8.417LF8.4171220248154A200 vectors / A700 details
Partition10.29LF10.2912246.960246.96A200 vectors / A700 details
Partition10.287LF10.28712246.8848198.88A200 vectors / A700 details
Partition9.517LF9.51712228.448180.4A200 vectors / A700 details
Partition9.668LF9.66812232.0448184.04A200 vectors / A700 details
Partition1.588LF1.5881238.12038.12A200 vectors / A700 details
Partition5.313LF5.31312127.524879.52A200 vectors / A700 details
Partition4.912LF4.91212117.8840.5377.35A200 vectors / A700 details
Partition5.72LF5.7212137.284889.28A200 vectors / A700 details
Partition4.912LF4.91212117.880117.88A200 vectors / A700 details
Partition5.72LF5.7212137.280137.28A200 vectors / A700 details
Partition15.22LF15.2212365.2840325.28A200 vectors / A700 details
Partition8.647LF8.64712207.5242.667164.853A200 vectors / A700 details
Partition6.297LF6.29712151.120151.12A200 vectors / A700 details
Partition2.247LF2.247UnmeasuredUnmeasuredUnmeasuredUnmeasuredA200 vectors / A700 details
Partition2.247LF2.247UnmeasuredUnmeasuredUnmeasuredUnmeasuredA200 vectors / A700 details
Partition2.407LF2.407UnmeasuredUnmeasuredUnmeasuredUnmeasuredA200 vectors / A700 details
02 / FULL RECORDED SCOPE

All 65 entries.
With their basis.

Each quantity keeps its unit, drawing reference and status. Unmeasured lengths and heights stay open. A lump-sum scope package is not a measured component count.

Showing 65 of 65 entries
Item & descriptionGrossDeductionsQuantity / unitDrawingStatus, basis & note
D-W01 / Partitionsfreestanding-12ft partition centerlineWall W017.70307.703LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W02 / Partitionsfreestanding-12ft partition centerlineWall W029.20309.203LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W03 / Partitionsfreestanding-12ft partition centerlineWall W0312.187012.187LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W04 / Partitionsfreestanding-12ft partition centerlineWall W049.20309.203LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W05 / Partitionsfreestanding-12ft partition centerlineWall W0510.333010.333LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W06 / Partitionsfreestanding-12ft partition centerlineWall W067.78707.787LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W07 / Partitionsfreestanding-12ft partition centerlineWall W0711.627011.627LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W08 / Partitionsfreestanding-12ft partition centerlineWall W084.5604.56LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W09 / Partitionsfreestanding-12ft partition centerlineWall W092.79702.797LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W10 / Partitionsfreestanding-12ft partition centerlineWall W103.89303.893LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W11 / Partitionsfreestanding-12ft partition centerlineWall W118.208.2LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W12 / Partitionsfreestanding-12ft partition centerlineWall W128.208.2LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W13 / Partitionsfreestanding-12ft partition centerlineWall W1315.43015.43LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W14 / Partitionsfreestanding-12ft partition centerlineWall W148.41708.417LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W15 / Partitionsfreestanding-12ft partition centerlineWall W158.41708.417LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W16 / Partitionsfreestanding-12ft partition centerlineWall W1610.287010.287LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W17 / Partitionsfreestanding-12ft partition centerlineWall W178.41708.417LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W18 / Partitionsfreestanding-12ft partition centerlineWall W1810.29010.29LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W19 / Partitionsfreestanding-12ft partition centerlineWall W1910.287010.287LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W20 / Partitionsfreestanding-12ft partition centerlineWall W209.51709.517LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W21 / Partitionsfreestanding-12ft partition centerlineWall W219.66809.668LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W22 / Partitionsfreestanding-12ft partition centerlineWall W221.58801.588LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W23 / Partitionsfreestanding-12ft partition centerlineWall W235.31305.313LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W24 / Partitionsfreestanding-12ft partition centerlineWall W244.91204.912LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W25 / Partitionsfreestanding-12ft partition centerlineWall W255.7205.72LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W26 / Partitionsfreestanding-12ft partition centerlineWall W264.91204.912LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W27 / Partitionsfreestanding-12ft partition centerlineWall W275.7205.72LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W28 / Partitionsfreestanding-12ft partition centerlineWall W2815.22015.22LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W29 / Partitionsfreestanding-12ft partition centerlineWall W298.64708.647LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W30 / Partitionsfreestanding-12ft partition centerlineWall W306.29706.297LFA200 vectors / A700 detailsPlan-measured review quantityGross minus stated deductions

D-W31 / Partitionsone-hour-full-height partition centerlineWall W312.24702.247LFA200 vectors / A700 detailsLength measured; board height and area openGross minus stated deductions

D-W32 / Partitionsone-hour-full-height partition centerlineWall W322.24702.247LFA200 vectors / A700 detailsLength measured; board height and area openGross minus stated deductions

D-W33 / Partitionsone-hour-full-height partition centerlineWall W332.40702.407LFA200 vectors / A700 detailsLength measured; board height and area openGross minus stated deductions

D-C-119 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope67.5067.5SFA400Plan-measured review quantityGross minus stated deductions

D-C-118 / Ceilings & stepsGypsum ceiling horizontal areaShared scope106.020106.02SFA400Plan-measured review quantityGross minus stated deductions

D-C-121 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope67.635067.635SFA400Plan-measured review quantityGross minus stated deductions

D-C-122-H / Ceilings & stepsGypsum ceiling horizontal areaShared scope62.055062.055SFA400Plan-measured review quantityGross minus stated deductions

D-C-122-L / Ceilings & stepsGypsum ceiling horizontal areaShared scope11.615011.615SFA400Plan-measured review quantityGross minus stated deductions

D-C-102 / Ceilings & stepsGypsum ceiling horizontal areaShared scope51.978051.978SFA400Plan-measured review quantityGross minus stated deductions

D-C-109 / Ceilings & stepsGypsum ceiling horizontal areaShared scope33.319033.319SFA400Plan-measured review quantityGross minus stated deductions

D-C-103 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope79.166079.166SFA400Plan-measured review quantityGross minus stated deductions

D-C-104 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope79.166079.166SFA400Plan-measured review quantityGross minus stated deductions

D-C-105 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope86.057086.057SFA400Plan-measured review quantityGross minus stated deductions

D-C-112 / Ceilings & stepsGypsum ceiling horizontal areaShared scope23.928023.928SFA400Plan-measured review quantityGross minus stated deductions

D-C-107 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope20.981020.981SFA400Plan-measured review quantityGross minus stated deductions

D-C-115 / Ceilings & stepsGypsum ceiling horizontal areaShared scope27.989027.989SFA400Plan-measured review quantityGross minus stated deductions

D-C-114 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope3.66703.667SFA400Plan-measured review quantityGross minus stated deductions

D-C-STAFF-12 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope76.659076.659SFA400Plan-measured review quantityGross minus stated deductions

D-C-STAFF-11 / Ceilings & stepsAcoustic ceiling / grid - separate scope allocationShared scope52.149052.149SFA400Plan-measured review quantityGross minus stated deductions

D-C-LAB / Ceilings & stepsGypsum ceiling horizontal areaShared scope86.335086.335SFA400Plan-measured review quantityGross minus stated deductions

D-C-STAFF-SOFFIT / Ceilings & stepsGypsum ceiling horizontal areaShared scope9.64109.641SFA400Plan-measured review quantityGross minus stated deductions

D-C-FRONT / Ceilings & stepsGypsum ceiling horizontal areaShared scope368.7580368.758SFA400Plan-measured review quantityGross minus stated deductions

D-FRP / Accessories & interfacesFRP-1 Marlite P100 White to 8 feet; separate trade allocationShared scope31.147031.147SFA500 legend-match bars / specification; A200 W10 runPlan-measured review quantityGross minus stated deductions

D-RECEP-STEP / Ceilings & stepsOne-foot vertical gypsum step around 11-foot islandShared scope37.917037.917SFA400 dimensions / 10-foot to 11-foot tagsPlan-measured review quantityGross minus stated deductions

Dimension-derived perimeter; confirm concealed edge construction before fabrication.

D-CANINE-STEP / Ceilings & stepsThree-foot vertical gypsum ceiling stepShared scope12.46012.46SFA400 canine 12-foot / 9-foot ceiling boundaryPlan-measured review quantityGross minus stated deductions

D-WOOD-BEAM-SUPPORT / Accessories & interfacesConcealed supports for three millwork-wrapped beamsWall WOOD-BEAM-SUPPORT303EAA400 C-3 notePlan-measured review quantityGross minus stated deductions

GC structural support design / attachment to confirm; not extra gypsum area.

D-ABOVE-INSUL / InsulationAcoustic batt plan coverage, four feet each side of partition; overlap removedShared scope1,377.72901,377.729SFA400 keynote 1; A200 measured partition centerlinesPlan-measured review quantityGross minus stated deductions

Coverage basis; confirm extent over open C-0 areas and required thickness.

D-BRACES / Accessories & interfacesPlanning brace stations at maximum four-foot spacing per runShared scope1080108EAA200 48-inch note; conflicting A700 alternativesPlanning count; bracing design unresolvedGross minus stated deductions

Conservative planning count, NOT approved structural design. Shared intersections / alternatives to resolve.

D-DEMO-AREA / RemovalExisting ceiling tile/grid removal - gross footprint basisShared scope2,001.38102,001.381SFA100 keynotes 1 and 2Plan-measured review quantityGross minus stated deductions

GC demolition allocation; existing wall/cabinet footprints and salvage require job-walk confirmation. Not additive new finish.

D-GRAB-BACK / Accessories & interfacesAccessible grab-bar steel backing setShared scope101SETA700 grab bar support / A802/17Plan-measured review quantityGross minus stated deductions

Plate lengths and attachments follow final fixtures.

D-RISERS / Accessories & interfacesFull-height service-riser pilastersShared scope303EAA200 keynote 3Plan-measured review quantityGross minus stated deductions

Cladding perimeter / deck height unavailable; no invented SF.

D-MILLWORK-BACK / Accessories & interfacesContinuous blocking / backing coordinationShared scope101LSA200 / A600 / A800-A802Plan-measured review quantityGross minus stated deductions

Do not price as a lump allowance without confirming actual support lengths / loads. See casework register.

D-DEMO-PART / RemovalSelective existing partition demolitionShared scope101LSA100 dashed existing wallsPlan-measured review quantityGross minus stated deductions

Separate GC/demo package; concealed heights / full partition LF to verify at walk. New partition LF is not demolition LF.

D-CAVITY-BATT / InsulationFull cavity sound batt, one cavity per wall (not two board faces)Shared scope2,484.20202,484.202SFA700 full batt note; half two-face net boardPlan-measured review quantityGross minus stated deductions

Known 12-foot walls only; rated deck-height batt remains additional.

D-EXIST-LEVEL4 / Accessories & interfacesExisting Level 4 preparation upper planning surfaceShared scope844.0780844.078SFA200 Level 4 note / existing wall tracesPlan-measured review quantityGross minus stated deductions

Existing opaque runs only; patching / full skim extent determined by substrate inspection. Not new board.

SF = square feet; LF = linear feet; EA = count; LS = lump-sum scope package. SF-PROJ is a plan projection, not developed installed surface. Reference schedules and procurement allowances are nonadditive to their parent scope.

03 / SUPPORTING REGISTERS

The detail behind
the scope.

Measurements, deductions and planning inputs expand the same scope. They are not additional purchases.

Ceiling measurement zones · 20 rows

20 geometry zones support 19 ceiling scope lines. These are supporting measurements, not extra ceiling purchases.

ZoneTypeHeight FTHorizontal SFDrawingBasis
Ceiling 01C-11067.5A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 02C-29106.02A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 03C-11067.635A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 04C-21262.055A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 05C-2911.615A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 06C-2951.978A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 07C-2933.319A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 08C-11079.166A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 09C-11079.166A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 10C-11086.057A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 11C-2923.928A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 12C-11020.981A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 13C-2927.989A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 14C-1123.667A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 15C-11276.659A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 16C-11252.149A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 17C-21086.335A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 18C-289.641A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 19C-210368.758A400Horizontal zone. Separate vertical steps and scope allocations are in the takeoff.
Ceiling 20C-0Unmeasured615.284A400Open-to-deck plan projection only. Excluded from installed ceiling totals and developed paint surface. The full dryfall projection has a separate basis.
Scheduled door openings · 18 rows

18 new scheduled doors. Two existing doors have no fabricated leaf dimensions. These openings support deductions and coordination; their counts are not added to board area.

OpeningWidth FTHeight FTOpening SFGlass SF / faceWallDrawingBasis
Door 00338240W20A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 00438240W21A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 00538240W19A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 00638240W17A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 00738240W14A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 00838240W13A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 00938240W13A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 0102.58200W28A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 01138247.333W12A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 01238247.333W25A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 0131.58120W33A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 0142.667821.3330W29A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 01538247.333W07A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 01638247.333W03A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 01738240W01A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 018382410.833W05A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 01938247.333W23A201 / A200Scheduled nominal opening; rough-opening tolerance not added.
Door 02033.7511.250Unhosted / coordinateA201 / A200Scheduled nominal opening. Door 020 is unhosted and is not added to modeled-wall deductions.
Interior glazing openings · 4 rows

Four interior glazing openings, used in the appropriate wall-face deduction register.

OpeningWallWidth FTHeight FTOpening SFSource
Glazing 01W036.79427.16A200 opening 259.14-381.36 points; 2/A201 surgery glazing
Glazing 02W121.4533.6675.329A200 glazing jamb vectors; 2/A201 feline glazing
Glazing 03W075.0474.522.71A200 glazing jamb vectors; 2/A201 typical Window C
Glazing 04W244.5034.520.265A200 4-foot-6-inch opening; 2/A201 typical Window C
Board opening deductions · 21 rows

Scheduled openings assigned to their host wall. Door 020 is unhosted and is not invented as a wall deduction.

WallOpeningSF per faceFacesDeduction SFSource
W01Door 01724248A200 vectors / A700 details
W03Door 01624248A200 vectors / A700 details
W03GL-SURGERY27.16254.32A200 vectors / A700 details
W05Door 01824248A200 vectors / A700 details
W07Door 01524248A200 vectors / A700 details
W07GL-CANINE22.71245.42A200 vectors / A700 details
W12Door 01124248A200 vectors / A700 details
W12GL-FELINE5.329210.658A200 vectors / A700 details
W13Door 00824248A200 vectors / A700 details
W13Door 00924248A200 vectors / A700 details
W14Door 00724248A200 vectors / A700 details
W17Door 00624248A200 vectors / A700 details
W19Door 00524248A200 vectors / A700 details
W20Door 00324248A200 vectors / A700 details
W21Door 00424248A200 vectors / A700 details
W23Door 01924248A200 vectors / A700 details
W24GL-ISO20.265240.53A200 vectors / A700 details
W25Door 01224248A200 vectors / A700 details
W28Door 01020240A200 vectors / A700 details
W29Door 01421.333242.666A200 vectors / A700 details
W33Door 01312224A200 vectors / A700 details
Planning material conversions · 3 rows

Stated source-report assumptions only. Package yield, waste, product approval and the supplier quote must be confirmed before ordering. Missing counts remain unmeasured.

Material / systemBasis quantityUnitAllowance %SF / unitPlanning countCount unitQualification
5/8-inch Type X wall board4,968.405SF1048114sheetsUnknown deck-height rated wall / pilasters; water-resistant board is a substitution subset, not extra SF. Planning assumptions only; final product / layout and supplier confirmation required.
Gypsum ceiling / vertical steps832.015SF103229sheetsProduct thickness and supporting-member layout to match final approved system. Planning assumptions only; final product / layout and supplier confirmation required.
ACT 2x4 field532.98SF10874tilesPlanning module count, NOT a grid shop layout; perimeter cut reuse / lighting / existing salvage subject to confirmation. Planning assumptions only; final product / layout and supplier confirmation required.
04 / BEFORE RELEASE

6 questions.
Still visible.

Drawing conflicts, field dimensions and trade interfaces stay with the quantities until they are resolved.

RFI-01 / OPEN

Confirm 12-foot free-standing wall design, brace spacing (48 inches vs 5/10 feet), 6-inch wet-wall locations, and missing 7/A701 detail.

Resolve with the responsible design / project team before pricing or ordering.

drywall-framing
RFI-02 / OPEN

Provide deck height, oxygen-closet rating/ceiling termination and pilaster developed dimensions; inspect existing demising insulation before replacement.

Resolve with the responsible design / project team before pricing or ordering.

drywall-framing
RFI-03 / OPEN

Specify epoxy and metal-trim paint system; confirm factory versus field door / beam stain, actual exterior glazing dimensions and dryfall developed surface area.

Resolve with the responsible design / project team before pricing or ordering.

painting
RFI-04 / OPEN

Confirm BASE-1 at LVT/tile, oxygen-closet floor finish, wall-tile elevation orientations, and floor finish sequence below fixed cabinetry.

Resolve with the responsible design / project team before pricing or ordering.

flooring
RFI-05 / OPEN

Confirm moisture / slab preparation, wall tile backing / membrane, sheet-vinyl cove and weld details, quantities of attic stock and minimum roll cuts.

Resolve with the responsible design / project team before pricing or ordering.

flooring
RFI-06 / OPEN

Confirm current addenda and trade allocation for FRP, acoustic ceilings, selective demolition, backing and access panels.

Resolve with the responsible design / project team before pricing or ordering.

all
05 / SOURCE & REVIEW BASIS

Trace the scope
to the drawings.

Client architectural permit set (identity withheld)
Submit for Build Permit, October 27, 2026
No separate document ID was assigned in the supplied source manifest.

Source sheet and physical PDF page register
SheetSource titlePhysical PDF page
A100Demolition plan3
A200Architectural floor plan4
A201Door and window schedules5
A400Reflected ceiling plan6
A500Millwork and finish plan7
A600Furniture and equipment layout8
A700Wall and construction details9
A800Interior elevations10
A801Interior elevations11
A802Interior elevations12
A900Millwork details13

Source PDF SHA-256
c360672d5a36ff70cf159b62981761b392956345815f390dfcda338c5a6de9ab

R10 quantity report, exported November 2, 2026

What has been checked

The original A200 9-foot dimension calibrates at 18 PDF points per foot. Original wall outlines independently reconstruct W03 at 12.186667 LF, agreeing with R10 at 12.187 LF. Its documented 12-foot height and two faces give 292.480 SF gross board.

What remains open

Native scale-confirmed flags remain false. This separate source check is not blanket approval of every sheet or field condition. Complete independent remeasurement and open-question resolution remain required for release.

  • W31-W33 total 6.901 LF of rated partition with unknown height. No board, batt or track height is fabricated from the model reference.
  • Board figures are known two-face net surfaces. Water-resistant board is a substitution subset; do not add it twice.
  • The 108 brace stations are a planning count with conflicting details, not an approved structural support design. Missing A701 detail and wet-wall assignments remain open.
  • Service-riser cladding, backing lengths and loads, existing demising conditions, rated assemblies and access details require confirmation.
  • Acoustic ceiling, FRP, demolition and backing allocations overlap finish coordination. Framing and finish are two views of the same anonymous project; do not sum both packages blindly.
  • The source report includes purchase assumptions. Waste, pack yield and final layout are provisional. No material quote, labor rate or final bid price is published.

Client names, project addresses, original plans, contact details, rates and private links are omitted. No final construction price is published.

Download anonymous quantity data ↓

YOUR NEXT SET OF PLANS

A scope you can inspect.
A workup you can use.

Send the plans, trade and deadline to start your measured package.

Send your plans ↗